<span id="r1w2e"></span>
    <track id="r1w2e"><em id="r1w2e"></em></track>

  1. <track id="r1w2e"><em id="r1w2e"></em></track>
      <span id="r1w2e"><output id="r1w2e"><b id="r1w2e"></b></output></span><ol id="r1w2e"></ol>
      1. 提交詢價信息
        發布緊急求購
        您好,歡迎來到儀器交易網!手機版|本站服務|添加收藏|幫助中心
        您所在的位置: 儀器交易網 » 供應 » 通用分析儀器 » 色譜 » 氣相色譜(GC) » 安捷倫6890玻璃柱Chromosorb 101 HP 60~80 醫用口罩及醫用防護服中環氧乙烷的測定

        安捷倫6890玻璃柱Chromosorb 101 HP 60~80 醫用口罩及醫用防護服中環氧乙烷的測定

        浩瀚色譜(山東)應用技術開發有限公司
        會員指數: 企業認證:         

        價格:電議

        所在地:山東 棗莊市

        型號:安捷倫6890玻璃柱Chromosorb 101 HP 60~80

        手機:15562228838(微信同號)13963221227(微信同號)

        電話:0632-5667636

        更新時間:2022-01-28

        瀏覽次數:346

        公司地址:山東省滕州市(市場部和技術部);中國香港(研發中心)

        15562228838(微信同號)13963221227(微信同號)   王經理(先生) 總經理  (來電時請說是從儀器交易網看到我的)

        產品簡介

        醫用口罩及醫用防護服中環氧乙烷的測定,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內空氣,焦爐煤氣,煉廠氣,天然氣,變壓器油溶解氣,醫療器械,環氧乙烷,乙醇,乙酸,胺

        公司簡介

        浩瀚色譜(山東)應用技術開發有限公司,是齊魯大地一家從事高端色譜儀器技術開發,技術推廣的高新技術企業,公司依托分析與測試中心及色譜工程研究所等科研單位,研發出多款新型產品。(一)專用色譜柱:1.氯乙suan直接進樣分析專用柱2.氯化氫直接進樣分析專用柱3.氯QI直接進樣分析專用柱4.四氟化硅直接進樣分析專用柱5.六氟二甲基硅醚分析專用柱6.氨氣直接進樣分析專用柱(二)痕量分析專用氣相色譜儀:1.高純氣體中痕量水(ppb級)分析專用氣相色譜儀2.純苯中痕量噻吩(ppb級)分析專用氣相色譜儀(三)防腐型氣相色譜儀,并成功應用于氟氣,氟化氫,氯QI,氨氣,酰氯,氯化氫,三氯氫硅,四氟化硅,氯YI酸,氯HUA亞砜,硫化物,二氯化硫等腐蝕性物質檢測,產品遍布各個行業及地區,其中不乏有大型央企---中石油,中儲糧,秦山核電站,中紡集團等,部分出口到伊拉克,哈薩克斯坦等國。

        公司主要業務

        1.通用氣相色譜儀生產銷售:氫火焰檢測器氣相色譜儀,熱導檢測器氣相色譜儀,火焰光度檢測器氣相色譜儀,氮磷檢測器氣相色譜儀,電子捕獲檢測器氣相色譜儀。

        2.便攜式氣相色譜儀,在線氣相色譜儀生產銷售。

        3.專用氣相色譜儀研發制造:氧化鋯檢測器氣相色譜儀,氦離子檢測器氣相色譜儀,氬離子檢測器氣相色譜儀等。

        4.防腐氣相色譜儀

        5.二維,多維氣相色譜儀

        6.高效液相色譜儀

        7.實驗室純水機,頂空進樣器,自動進樣器,熱解析儀,氮氫空發生器,色譜耗材(色譜柱,石墨墊,穩壓閥,壓蓋鉗,頂空瓶,7725進樣閥等),分光光度計,電子天平,水分測定儀,干燥箱,離心機,玻璃儀器,化學試劑等整套實驗室設備生產銷售。

        8.提供技術轉讓,建立分析方法。

        9.從事舊色譜以舊換新的業務。

        10.色譜柱研制,定做。

        11.承接樣品的檢測業務。

        12.承接國內外色譜儀器的維修,改裝業務。

        浩瀚色譜(山東)應用技術開發有限公司,以客戶為中心,想客戶所想,銷售的不僅僅是產品,重要的是幫助客戶解決問題,架起心靈溝通的橋梁。


        展開

        產品說明

        醫用口罩及醫用防護服中環氧乙烷的測定
        醫用口罩及醫用防護服中環氧乙烷的測定 詳細信息:

        Chromosorb 101  HP 60~80目;玻璃柱長2m*3 mm
        適用于:安捷倫6890,7820,7890,8860,8890,4890,5890

        在這次新冠肺炎疫情防控期間,為保證防疫物資及時供給,國務院應對新型冠狀病毒感染的肺炎疫情聯防聯控機制醫療物資保障組印發了《關于疫情期間執行醫用一次性防護服輻照滅菌應急規范(臨時)的通知》(以下簡稱《應急規范》).目前,我國國標醫用防護服大多采用環氧乙烷滅菌,需要7~14天時間,根據《應急規范》采用輻照滅菌技術,則將這個時間縮短到1天以內.

        浩瀚色譜(山東)應用技術開發有限公司建立頂空-氣相色譜法測定醫用口罩和醫用防護服中環氧乙烷殘留量的分析方法。通過實驗優化了測定方法和條件,確定了色譜柱類型、頂空平衡時間和平衡溫度,并進行了加標回收實驗。在相應的濃度范圍內線性關系良好,r=0.9996,環氧乙烷最低檢出限為0.02μg/mL,當稱樣量為1.0g,定容體積為5mL時,檢出限為0.1μg/g。方法可以滿足標準要求,對口罩和防護服中環氧乙烷殘留量檢測具有重要意義。

        醫用口罩及醫用防護服中環氧乙烷的測定  測試譜圖:



        Determination of ethylene oxide in medical masks and medical protective clothing
        Determination of ethylene oxide in medical masks and medical protective clothing Details:

        Chromosorb 101 HP 60~80 mesh; glass column length 2m*3 mm
        Applies to: Agilent 6890, 7820, 7890, 8860, 8890, 4890, 5890

        During this new crown pneumonia epidemic prevention and control period, in order to ensure the timely supply of epidemic prevention materials, the State Council's Joint Prevention and Control Mechanism for the New Coronary Virus Infection Pneumonia Epidemic Prevention and Control Mechanism Medical Materials Security Group issued the "Irradiation Sterilization of Medical Disposable Protective Clothing During the Epidemic Period". Emergency Specifications (Temporary) Notice" (hereinafter referred to as "Emergency Specifications"). At present, most of my country's national standard medical protective clothing is sterilized by ethylene oxide, which takes 7 to 14 days. According to the "Emergency Specifications", irradiation sterilization is used. Technology reduces this time to less than 1 day.

        Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has established an analytical method for the determination of ethylene oxide residues in medical masks and medical protective clothing by headspace-gas chromatography. The determination method and conditions were optimized through experiments, the column type, headspace equilibrium time and equilibrium temperature were determined, and standard addition and recovery experiments were carried out. The linear relationship is good in the corresponding concentration range, r=0.9996, the minimum detection limit of ethylene oxide is 0.02μg/mL, when the weighing sample is 1.0g and the constant volume is 5mL, the detection limit is 0.1μg/mL g. The method can meet the standard requirements and is of great significance for the detection of ethylene oxide residues in masks and protective clothing.

        Determination of ethylene oxide in medical masks and medical protective clothing Test spectrum: 



        本頁產品地址:http://www.hsqh8.com/sell/show-9235327.html
        免責聲明:以上所展示的[安捷倫6890玻璃柱Chromosorb 101 HP 60~80 醫用口罩及醫用防護服中環氧乙烷的測定]信息由會員[浩瀚色譜(山東)應用技術開發有限公司]自行提供,內容的真實性、準確性和合法性由發布會員負責。
        [儀器交易網]對此不承擔任何責任。
        友情提醒:為規避購買風險,建議您在購買相關產品前務必確認供應商資質及產品質量!

        發布詢價單

        您最近瀏覽過的產品

        沒有合適的產品?是否在線詢價?
        詢價標題
        聯系人
        電話
        主要內容
        驗證碼  
        521AV

          <span id="r1w2e"></span>
          <track id="r1w2e"><em id="r1w2e"></em></track>

        1. <track id="r1w2e"><em id="r1w2e"></em></track>
            <span id="r1w2e"><output id="r1w2e"><b id="r1w2e"></b></output></span><ol id="r1w2e"></ol>